Securing MC Cable | Information by Electrical Professionals for ...
Feb 7, 2025 · For MC Cable, PI No. 2883-NFPA 70-2023 reads almost identical to the PI on NM cable, just with the name changed. You could still use tie wire if UL 2239 has standards for tie wire. You'll just need to get UL 2239 listed tie wire. I'll leave it to you to check UL 2239 on what it has to say on the topic. Cheers, Wayne
AC vs MC Cable | Information by Electrical Professionals for …
Oct 28, 2011 · AC cable typically has no ECG, just the bondstrip-and-cable armor. However, the armor of the AC cable can be used as an ECG. MC cable consists of an outer jacket of thin metal armor and is filled with individually insulated conductors which are contained in a jacket. MC cable has an ECG, but the armor isn't suitable for grounding.
MC/BX/AC, please clarify. Also, what cut and bush do you use?
Nov 14, 2024 · AC is armored cable made with paper individually wrapping the conductors and a thin aluminum bonding strip which with the armor serves as the EGC. BX is a slang name for AC. Metal Clad or MC cable is different. Regular MC has a green EGC, MC-ap has a #10 aluminum conductor in contact with the armor to create the EGC.
AC vs. MC vs. MC Lite | Information by Electrical Professionals for ...
Mar 21, 2003 · Re: AC vs. MC vs. MC Lite Spelling it out in a spec is the easy part. Sometimes chnages in contract occur without detailing each item, such as the type MC (or steel compression couplings vs cast). I was curious if Type MC automatically covered the steel aspect, or is no MC spec complete without a steel or aluminum choice.
MC cable firestopping UL interpretation | Information by Electrical ...
Nov 19, 2024 · 1) You can use _any_ MC cable up to a maximum of 3C+ground #8 AWG. 2) You can use an MC cable classified under the 'through penetrating products' category. When I did a search for 'through penetrating products' I found datasheets for various firestop assemblies, and those datasheets specified the specific MC cable they were listed with.
EMT vs MC | Information by Electrical Professionals for Electrical ...
Sep 7, 2010 · I was taught that, in concealed work, for the most part running MC is more efficient than EMT. With MC you have both raceway and conductors installed in one shot. Say I was hypothetically quoted 100 feet of ? EMT @ almost thirty bucks Fittings (couplings, connectors, unistrut clips) came out...
MC Cable Labor | Information by Electrical Professionals for …
Oct 18, 2023 · 12/2 MC Steel Armor w/ supports and connectors Generally speaking here regarding install . Me and a friend have pretty different labor units per thousand. Standard height ceiling, ceiling not installed yet. Supported either a bridle ring on flange, or KX clip on rod by others. 500' with 15...
MC in Damp location | Information by Electrical Professionals for ...
Nov 9, 2020 · Conductors within Southwire Armorlite MC cable are THHN/THWN, so that tells me you're good for damp locations with the conductors. Just check the MC jacket. NEC states you can use MC in wet locations as long as it meets what the text says. NEC 330.10(A). What kind of connectors are you using which would not be acceptable?
MC cable a raceway? | Information by Electrical Professionals for ...
Jan 18, 2009 · The situation at hand involves a Smoke Control System wired with Fire Alarm type MC cable as the SLC (Signal Line Circuit).The fire protection specialist has indicated that according to the International Fire Code/International Building Code-which is their governing code for this large metropolitan area-that the SLC does not meet its provisions ...
Plastic zip ties to hold MC cable, in a commercial blg?
Feb 16, 2017 · Ran 50' of MC cable down a hall way above a suspended ceiling. There was this gorgeous piece of 1" rigid aluminum conduit heading to the same location. Couldn't resist myself and violated the heck out of 300.11 B I may be going to hell for that one!