About 143,000 results
Open links in new tab
  1. PVC conduit vs plumbing pipe | Information by Electrical …

    Sep 29, 2021 · Another difference that you’ll find between PVC pipe and PVC conduit, is in the thickness of the wall of the pipe. The wall of plumbing PVC pipe is typically thicker than the wall of PVC conduit. Because plumbing PVC is used in applications that have pressure to consider, the added thickness ensures that the pipe is strong enough to resist ...

  2. Connecting PVC to EMT conduit - Mike Holt's Forum

    Mar 26, 2021 · Hello everyone. I have a non-metallic raceway (3/4", PVC Sch40) installed outdoors, buried underground, and it needs to rise above grade and continue its path along the surface of an exterior wall. What is the proper way to transition from a PVC conduit to an EMT conduit, as per NEC...

  3. pvc pipe ran within a concrete beam | Information by Electrical ...

    Jan 8, 2014 · I've inserted pipe through walls, or pipe vertically with-in walls all per their design. Let them pour the footer and the column and attach outside of both. Or run under the footer, or down the length outside the footer, but not in it.

  4. Transition of RGS conduit to PVC conduit | Information by …

    Jan 8, 2019 · I have a situation where there is a transition of RGS Metal conduit from above ground to PVC conduit Under ground. The spec says to use " a threaded PVC to rigid metal conduit adapter" for transition. Can somebody help me to send the catalogues of the manufacturer for the required adapter. I...

  5. Cutting pvc pipe without removing wires | Information by Electrical ...

    Feb 22, 2010 · There are several methods to use if you need to cut occupied PVC. The method depends on the circumstances. Tubing cutter is clean but you need to have room to work and big enough cutters. Ringing with PVC cutters is a little more dangerous and, again, you have to have room to work and big enough cutters.

  6. Pull string in PVC | Information by Electrical Professionals for ...

    Nov 19, 2010 · On long, high runs of intermediate size pipe, like 1 1/4", I'm finally learning to run twine as I run pipe. But only after wasting plenty of time trying to snag 200' fishtapes from either end first. At least PVC is more airtight than setscrew couplings. For PVC I carry a roll of cheap 1/4" nylon rope, then pull in the tugger rope for larger cable.

  7. PVC SCH 40 underneath a concrete slab in a building

    Sep 13, 2015 · What is the minimum cover requirement for PVC Sch 40 underneath a concrete slab inside of a building? I am running 2" pvc for a chase for low voltage (under 50v) it is within the exterior walls but passing through one interior stem wall. I am referring to table 300.5 ( 0-600v), minimum...

  8. Gray vs White PVC | Information by Electrical Professionals for ...

    Jun 10, 2014 · The wall thickness of Sch40 steel pipe and Sch40 PVC pipe is identical for a given pipe size but the pressure limit is very different. That said, for any given range of sizes and for a specific material you can associate a maximum pressure with Sch40, Sch80, etc. BTW, in my earlier post I mentioned Category 200. That should have been Class 200 ...

  9. Rigid vs. PVC for Service Entrance Mast | Information by Electrical ...

    Oct 31, 2003 · Re: Rigid vs. PVC for Service Entrance Mast We usually use 2" rigid here.Some of the older homes have SE cable. Pvc for an oh service is not common here unless its a pole service for a mobile home. Most new services here are underground,an OH is a rare bird.I think we've built 1 new OH in the last 5 yrs other than a few repairs of existing ones.

  10. Underground Wiring in PVC Conduit | Information by Electrical ...

    Sep 6, 2011 · A PVC pipe under ground, even if under a house slab, is considered a wet location. Pvc conduit runs outside almost always fill with water, unless you clean the joints real well and use primer then they might stay dry but it really doesnt matter, unless the …