![](/rp/kFAqShRrnkQMbH6NYLBYoJ3lq9s.png)
Orifice Plate - an overview | ScienceDirect Topics
An orifice plate has an opening that is smaller than the pipe diameter. The typical orifice plate has a concentric, sharp-edged opening. Because of the smaller area, the fluid velocity increases to cause a corresponding decrease in pressure. The flow rate can be calculated from the measured pressure drop across the orifice plate.
Parametric analysis of orifice plates on measurement of flow: A …
May 1, 2022 · The orifice plate, commonly used is thin, concentric, and square-edged. A concentric orifice plate can be used for bidirectional flow. Otherwise, the text quoted on the orifice plate decides the upstream side of the plate. A concentric square edge orifice has minimal contact with the fast-moving liquid and is used for clean fluids.
Orifice Meter - an overview | ScienceDirect Topics
An orifice meter consists of an orifice plate, a holding device, upstream downstream meter piping, and pressure taps. By far the most critical part of the meter is the orifice plate, particularly the widely used square-edged concentric plate, whose construction requirements are well documented in standards such as AGA-3 and ISO 5167-1.
Orifice plate cavitation mechanism and its influencing factors
Sep 1, 2010 · The orifice critical cavitation number is closely related to the orifice plate size, and especially closely related with the ratio of the orifice plate radius to the tunnel radius. The approximate formula for the critical cavitation number of the square orifice plate that only considers the main influencing factor was obtained by model experiments.
Noise optimization of multi-stage orifice plates based on RBF …
Dec 1, 2022 · For the water supply systems with large flow rate, high pressure drop and short pipeline distance, the single-stage orifice plate is not suitable. It will result in excessively high local flow velocity, fluid cavitation, and severe noise. The MSOP can realize the high pressure drop due to its multi-stage pressure reduction structure.
Experimental study on effect of structural parameters on pressure …
Jun 1, 2023 · According to ISO5167-2 [25], the pressure taps of the orifice plate were located at a distance of 1D (pipe diameter D) from the upstream of the orifice plate and 6D downstream of the orifice plate. Because the range of the differential pressure of the orifice plate to be measured is large, the appropriate range of meters must be selected ...
Plate Orifice - an overview | ScienceDirect Topics
A critical component in a meter run is the orifice plate. Most often, the orifice plate is a thin, flat, circular disc, made of metal, having a flat handle. Depending on the methods being used and the data being gathered, different orifice plates types are installed. Figure 12.11 provides examples of various orifice plate configurations ...
The orifice plate discharge coefficient equation — further work
Apr 1, 1995 · The EEC orifice plate project: index to the data tables. Progress Report No PR13:EUEC/17 (EEC005), National Engineering Laboratory Executive Agency, Glasgow, UK, 1992 114 M.J. Reader-Harris et al. 18 Spencer, E. A. Bibliography of the EEC orifice plate project.
The orifice plate discharge coefficient equation - ScienceDirect
Jan 1, 1990 · Orifice plate meters have been evaluated in terms of the influences of various fluid flow characteristics, such as multi-phase flow [14–16], pressure loss [17,18], beta ratio [19], discharge coefficient [20,21] and fluid types, including geothermal flow streams [22,23].
Experimental study on enhancing thermoelectric performance of …
Jan 1, 2025 · The performance of a flexibly assembled multi-orifice plate in enhancing exhaust heat transfer within exhaust thermoelectric generator was experimentally analyzed. The results showed that incorporating a multi-orifice plate significantly increased output power, with the optimal installation position achieving a 58.8% improvement and a more ...